Description
Overview
- State-of-the-art technology and versatility
- Easily adaptable to the machine structure
- Maximum application flexibility with configurable advanced functions
- Complete diagnostic and monitoring online
- No dead zone
- Pigtail cable with M12 connector
- Cascade connection of up to 3 units
- Up to 20m operating range and 1800m protected height
- Compact dimensions (35 x 41 mm section)
- Anti-interference coding
- Integrated Muting function
- Floating Blanking, Fixed Blanking and Reduced Resolution
- Configurable with Autoteaching, Pushbuttons for common configuration, Graphic User Interface for complete parametrisation
- Ethernet Interface for programming, monitoring and error logging
APPLICATIONS
Automatic machines Robots
Automatic assembling lines
Palletizers and Depalletizers
Technical Specification
SG2 MUTING [SG2-30-xxx-OO-W] |
SG4 EXTENDED [SG4-xx-xxx-OO-P] |
SG4-N [SG4-xx-xxx-OO-N] |
||
---|---|---|---|---|
GENERAL DATA | ||||
Type (EN61496-1-2) | 2 | 4 | ||
PL (EN ISO 13849-1) | c | e | ||
SIL (IEC 61508) | 1 | 3 | ||
Resolution | 30 mm | 14, 30 mm | ||
Protected heights | 300 … 1800 mm (with 150 mm steps) | |||
Operating distance | 0.2 … 20 m | 0.2 … 7 m (14 mm resolution) 0.2 … 20 m (30 mm resolution) |
||
Dead Zone | No dead zone | |||
Cascade connection | …. | Up to 3 units | …. | |
ELECTRICAL DATA | ||||
Power supply (Vdd) | 24 Vdc ± 20 | |||
Outputs | 2 PNP, with short circuit protection 2 PNP |
|||
Output current | 0.5 A max/each output | |||
Capacitive load | 2.2 uF @ 24Vdc max | |||
Response time | 13 … 22 ms depending on model * | 13 … 33 ms depending on model * | 15 … 33 ms depending on model * | |
Cables length (for power supply) | 50 m max | |||
MECHANICAL AND ENVIRONMENTAL DATA | ||||
Operating temperature | 0 …+50 °C | |||
Humidity | 15 … 95 % (no condensation) | |||
Mechanical protection | IP 65 (EN 60529) | |||
Housing material | Painted aluminium, Polycarbonate, PBT | |||
Window material | PMMA | |||
FUNCTIONS | ||||
Test Input | ||||
Manual/Automatic Restart | ||||
External Device Monitoring (EDM) | ||||
Anti-interference coding | ||||
Range reduction | ||||
T Muting/L Muting | ||||
…… | Partial Muting | |||
…… | Filter on muting signals | |||
Muting dependent Override | ||||
Floating Blanking | …… | |||
Fixed Blanking | …… | |||
Max. Number of Blanking Areas | 2 | 5 | …… | |
…… | Reduced Resolution | …… | ||
NOTES | ||||
* The response time depends on model; when a cascaded system is used, depends also on the number of units connected. For detailed informations refer to related Product Datasheet or Manual. | ||||
1) The use of any type of blanking is not compatible with the use of Muting and Muting dependent Override. 2) In order to use Muting or Blanking with SG4 EXTENDED, the correct pigtail cable must be used (see accessories table) |
Let us know your requirements
Just send us your questions we will give
you the help you need.
you the help you need.
Reviews