Description

Overview

APPLICATIONS

Presence of all medium and large sized objects on conveyors

Critical object detection in front of problematic background

Critical shiny surface object detection

Positioning tasks in palletizing

Position limiter for deck and robot in automotive manufacturing

Collision prevention limit switch for AGV applications

Checking filling level for liquid and objects

Technical Specification

Supply voltage 24 VDC ± 20%
Consumption < 2.2 W (excluding any loads)
Operating Distance 0.3..5 m (90% white) / 0.3..4.5 m (18% grey) / 0.3..3.5 m (6 % black)
(Models S65…OO, …OOZ, …OOI, …OOV)
0,3..4 m (90% white) / 0,3..2,6 m (18% grey) / 0,3..2 m (6% black) (Model S65…M53)
Hysteresis 30mm / 50mm / 80mm
Response time 8.5 msec max.
30 msec max. (S65…M53)
Difference White 90%/Grey 18% and White 90%/Black 6% see chart (value Typ, 1σ, T=25°C, ambient light <1Klux)
Repeatability error 20mm for distance > 750mm / 40mm for distance <= 750mm (1σ, T=25°C)
Thermal compensation error 1.5 mm /°C (T ≠ 25°C)
Switching output Can be set up (PNP NPN / Light Dark) 100mA max.
Voltage output 0…10V (S65…OOV)
Current output 4…20mA (S65…OOI)
Teach-in Input Active High ( +24V ) 1 sec < t < 3 sec: teach Q1 / > 3 sec: teach Q2
Warming-up time 20 min typ
Warnings Q1 (YELLOW) / Q2 (YELLOW) / ON PWR (GREEN) – PNP / NPN (GREEN)
Operating temperature -15°… +55 °C (with device ON)
Storage temperature -25 … +70 °C
Electrical strength 500 VAC, 1 min between electronics and case
Insulation resistance > 20 MΩ, 500 VDC between electronics and case
Reading spot size typ 200×200 mm @ 4m
Pointer spot size (green) typ 250×250 mm @ 4m
Max. deviation of pointer/reading spot axes origin +/- 40 mm
Emission and Wavelength LED IR / 850 nm
Ambient light rejection according to EN 60947-5-2,
Vibrations width 0.5 mm, frequency 10 … 55Hz, per axis (EN60068-2-6)
Shock resistance 11 ms (30 G) 6 shocks for each axis (EN60068-2-27)
Humidity < 90% no condensation
Exposed material Body ABS / Display POLYESTER
Front side material PMMA
Mechanical protection IP67
Connections M12 – 5 poles
(Overall) Dimensions 50 x 50 x 25 mm
Weight 50 g.max
I/O LINK Connection NO (See parameter table on www.datalogic.com)
UL (requirements) Class 2 power supply according to UL 508

Let us know your requirements

Just send us your questions we will give
you the help you need.

Reviews

There are no reviews yet.

Be the first to review “S65-M”

Your email address will not be published. Required fields are marked *